1. 20 years - Andeli Group Co.,Ltd is founded in 1993.
2. 12 share holding companies - Andeli have owns 12 share holding companies in Shanghai, Hunan, Zhejiang, UAE.
3. 300 cooperating companies - We have over 300 cooperating companies.
4. 3000 workers - We have over 3000 workers.
5. USD150,000,000 - The total assets is USD150,000,000.
6. 235,000 square meters - The area of Andeli is 235,000 square meters.
7. Certification - We have passed ISO9001:2000 Quality Management System and CCC, ROHS, CE, CB, SIMKO, KEMA...
AC Ammeter
Model: AM-96 AM-72 AM-48
Class: 1.5
Specs: 0.1A 0.5A 1A 1.5A 3A 5A 7.5A 10A 15A 20A 25A 30A 50A 75-105A(use
Ext. CT 5A)
Note: For60/75/100A direct meter, the class is 2.5.
Advantage: The scale can be easily changed without opening the front frame so
That the class will not be influenced.
DC Ammeter
Model: AM-96 AM-72 AM-48
Class: 1.5
Specs: 25uA 50uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 150mA
200mA 250mA 300mA 500mA 1A 3A 5A 7.5A 10A 20A 30A 50A 75-105A(used
With Shunt)
Feature: The scale can be easily changed without opening the front frame so that
The class will not be influenced.
DC Voltmeter
Model: AM-96 AM-72 AM-48
Class: 1.5
Specs: 3V 5V 7.5V 10V 15V 20V 50V 75V 100V 120V 150V 200V 250V 300V
400V 450V 600V
Note: Over 600V should be used with Ext. Resistor. (Rated Cuuent 5mA).
AC Voltmeter
Model: AM-96 AM-72 AM-48
Class: 1.5
Specs: 30V 50V 75V 100V 120V 150V 250V 300V 450V 600V For 450-380KV,
DC Voltmeter
Model: AM-96 AM-72 AM-48
Class: 1.5
Specs: 3V 5V 7.5V 10V 15V 20V 50V 75V 100V 120V 150V 200V 250V 300V
400V 450V 600V
Note: Over 600V should be used with Ext. Resistor. (Rated Cuuent 5mA).
AC Voltmeter
Model: AM-96 AM-72 AM-48
Class: 1.5
Specs: 30V 50V 75V 100V 120V 150V 250V 300V 450V 600V For 450-380KV,
MODEL: AM-96 AM-80 AM-72 AM-60 AM-50
Struction: Moving Coil, Moving Iron and Rectifier.
Class: 2.0 2.5
POWER METER
Wattmeters with built-in converter for 1 phase, 3P 3W, 3P 4W.
Model: AM-96 AM-72
Class: 1.5
Voltage: 50V 100V 220V 240V 220/380V 240/415V
Current: 5a
These meters are used with potential secondary voltage 100V voltage transformer
Or secondary current 5A CT. Wattmeters with built-in converter for 3P 3W, 3P 4W
And single phase.
POWER FACTOR
For 3 phases circuits, balanced load 45-65Hz and for 1 phase AC 50Hz.
Model: AM-96 AM-72
Class: 2.5
Voltage: 100V 380V 440V
Frequency: 50Hz 60Hz
Scale graduation: 0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.
3ind.
Orders to be Noted:
Type of Current: 1P, 3P 3W circuits, balanced load.
Rated Volt: The voltage is line voltage(between two wires).
Operating Current: If used with CT, the secondary current 5A or 1A is standard.
Should be used with potential transformer secondary voltage 100V.
Should be used with potential transformer secondary voltage 100V.
About us
Name |
Specification |
Remarks |
AC Ammeter |
30-10000uA, 1-1000mA, 1-50A, 1K-10KA |
Direct connection with EXt.shunt |
AC Voltmeter |
40-10000uA, 1-1000mA, 1-50A, 1K-10KA |
Direct connection with EXt.shunt |
DC Ammeter |
1-1000mA, 1-50A, 5-1000A, 1K-10KA |
Direct connection with EXt.shunt |
DC Ammeter |
40-1000mA, 1-1000V 1K-380kV |
Direct connection with EXt.shunt |
Frequency meter |
Voltage: 50-380V
Frequency:45-55Hz, 45-65Hz, 55-65Hz |
Only AM-80 is available |
Power factor meter |
Voltage: 50-380V
Frequency: 0.5cap-1-0.5ind; 0.3cap-1-0.7ind;
0.4cap-1-0.4ind; 0.7cap-1-0.3ind;
Suitable for 1 Por 3P3W circuit |
Only AM-80 is available |
Power meter |
Voltage: 50-380V Current: 0.2-5A
With current or voltage transformer |
Only AM-80 is available |