Rated Voltage: Single-phase 220V, Three-phase 380V
Type: ADL800-2004, ADL800-2007, ADL800-2015, ADL800-2022, ADL810-4007, ADL810-4015, ADL810-4022
Applicable motor power(KW): 0.4, 0.75, 1.5, 2.2, 0.75, 1.5, 2.2
Rated current(A): 3, 5, 8, 11, 2.5, 3.7, 5.5
| Item | Specification | |
|---|---|---|
| Output | Out voltage | Three phase 0~220V |
| Output frequency range | 0.1~60.0Hz,adjusable at 25.0~60.0Hz | |
| Power | Voltage and frequency | Single phase 220V±20%; 50~60Hz±5% |
| Control | Control mode | SVPWM Full digital space voltage vector control; adjustable at carrier frequency 1~12kHz |
| Carrier frequency | Settable at 0.0~25.0Hz | |
| Resolution of output frequency | 0.1Hz | |
| Resolution of setted frequency | Digital setting:0.1Hz,simulation input (outter terminal ) setting:1% of highest frequency | |
| V/F curve | Straight line type; basic frequency can be setted at 250~60.0Hz . | |
| Torque compensate Overload capacity | Straight line mode, compensate voltage ange:0~30% 1 minute at 150% of rated current | |
| Stop mode | Decelerate stop / free stop optionally. | |
| Working mode | Forward / reverse optionally | |
| DC brake | DC braking start frequency:0.0~15.0Hz; braking time:0.0~10.0s,braking voltage:0.0~50V | |
| Frequency setting | Control panel input,external potentiometer,panel potentiometer,external simulation voltage signal DC 0~5V | |
| Accelerate and decelerate time | 0.1~6000.0 seconds (accelerate and decelerate can setted respectively) be | |
| Multi-speed running | Photoelectric isolation, effective when shorted connect with COM terminal | |
| Higher and lower limit frequency | Higher limit frequency (lower limit frequency~highest frequency),lower limit frequency(0~higher limit frequency) can be random setted. | |
| Other functions | Past 4 times fault record, dynamic data amend | |
| Input and output signal | Control panel | Display:5 position 8 section LED(red),data setting:6 switch keys. |
| Outter terminal input | Forward (FWD),reverse •REV•multi speed input x1, x2 | |
| Protection | Protect function | Protection of over-voltage,over-current,overload,overheat and under-voltage. |
| Standard | GT/T12668.2~2002 / IEC61800-2 |